❶ 燃氣鍋爐房電氣必須防爆嗎

室外燃氣鍋爐電氣設備不用考慮防爆。只有在燃氣分配站區域的電氣設備要考慮防爆。

❷ 燃氣鍋爐房鍋爐間電氣設備要求防爆嗎

一般情況下,燃氣鍋爐房的電氣設備是沒有防爆要求的。按要求做好管道的防靜電接地就足夠了。

❸ 求一位大俠幫忙把論文翻譯成英文~100分 謝謝 燃氣鍋爐房的電氣防爆設計 摘 要:通過分析燃氣鍋爐房事故原

2 accident reason analysis

Analysis of gas boiler room the cause of the accident, there are two possible: boiler ontology explosion, boiler room to explode gas explosion concentration and explosions.

Boiler blast furnace body, because be in, or flue gas mixture in explosive existence, when achieved by fire or explosion limit, boiler heat ignites causing accidents in itself. This point and the national norm of building fire system that conform to the relevant provisions. The actual current boiler proct has considered safe proction measures to avoid it. Qualified gas boiler itself has the explosion-proof process design, such as burner in abnormal situation automatic stop, self-control device also stop output fuel, Gas boiler combustion system higher automatization, including the gas pressure is high, low limit alarm protection, when the control logic where step does not meet the conditions set start corresponding interlock protection.

Avoid the boiler exploded possibility, but still ontology exist above another possibility, can avoid? How to avoid it?

Three measures

In fact in design, according to the boiler design code "and" automatic fire alarm system design code "GB50116-1998 etc standard, we have taken the following measures:

Natural gas pipelines valves, meter, may occur gas leak place, boiler room may proce gas storage proct area [relative density 0.8, it is to be in commonly roof area in these areas], all equipped with combustible gas concentration measurement alarm device, according to combustible gas concentration situation give out sound and light alarm signal and start exhaust fan, when leakage accident concentrations reach explosion limit of the lower limit 50% [this value for reference only], but also immediately close natural air intake ct total intake solenoid valves.

In the boiler room and a natural gas pipeline in and out of the room, the incident, but also with the smoke exhaust fan combustible gas alarm interlocking (start).

Electrical, instrument by cable selection TongXin, not less than 1.5 mm2 minimum section.

Gas radiation tube tube top or the nearby, the lightning rod should be installed above the pipe jacking tip should be not less than 3m, and its scope of protection tube top above not less than 1-m.

Gas pipeline should be static grounding device that, when pipeline as metal materials, and lightning protection or electrical engineering protective grounding wire connected, the measured resistance R more than 4 Ω. In pipe joints, such as the bend, flange, valve and pipe with good place cannot metal contact, also with metal soft line will be both ends jumper.

In the boiler room and a natural gas pipeline in and out of the room door, window take pressure measures.

According to the explosion and fire dangerous environment electrical device design specification "the laws 2.2.2 bar, accord with one of the following conditions may, when the explosion danger area: devin in item 3, in the process of proction use fire equipment near, A combination of these several measures can clearly, electrical equipment selection for the explosion.

At the same time according to the explosion and fire dangerous environment electrical device design specification "the laws 2.2.2 bar, accord with one of the following conditions may, when the explosion danger area devin: the first 2 items, and the highest possible flammable explosive chroma does not exceed 10% of the lower limit, Close air intake ct natural total intake solenoid valves, concentration exceed 10% of the lower limit explosion limit, boiler room near the roof area are gas storage proct area, so lighting lamps and lanterns and switch choosing is explosion-proof type.

4 conclusion

In gas boiler room electrical design, lighting choose explosion-proof lamps, other part adopts the explosion-proof type.

references

[1] boiler design standard. GB50041-1992.

[2] explosion and fire dangerous environment electrical device design standard. GB50058-1992.

[3] the code for fire protection design of buildings. GB50016-2006.

[4] automatic fire alarm system design standard. GB50116-1998.

閱讀全文

與燃氣鍋爐房電氣防爆相關的資料

熱點內容
河北安宏五金製品銷售有限公司 瀏覽:323
帝王潔具五金件是什麼牌 瀏覽:395
江門朋益實業五金製品 瀏覽:662
軸承鋼做軸還需要怎麼處理 瀏覽:262
手機搬家怎麼連接設備 瀏覽:202
dg20設備是什麼機床 瀏覽:115
2016年防雷裝置檢測題庫 瀏覽:598
dos工具箱啟動不了 瀏覽:456
wincc機械手怎麼畫 瀏覽:709
環保機械行業有哪些商機 瀏覽:329
機械自我介紹工作經歷怎麼寫 瀏覽:550
大象是超聲波還是次什麼 瀏覽:598
uggc工具箱的幫助文件在哪裡 瀏覽:475
在鑄造實訓過程中有什麼收獲 瀏覽:684
排氣管里有閥門怎麼去掉 瀏覽:317
膠帶廠需要什麼機器設備 瀏覽:951
桿杠平衡實驗裝置 瀏覽:318
機械表中用於施工部位如何填寫 瀏覽:392
康師傅展示櫃加什麼製冷劑 瀏覽:65
砂缸泵怎麼換軸承視頻 瀏覽:416