A. 燃氣鍋爐房內的循環水泵一定要防爆型的嗎

燃氣鍋爐房內的循環水泵一定要防爆型的,因為燃氣鍋爐用的是燃氣,如果有泄漏,用普通泵可能有潛在危險。
來自南陽中天防爆

B. 求一位大俠幫忙把論文翻譯成英文~100分 謝謝 燃氣鍋爐房的電氣防爆設計 摘 要:通過分析燃氣鍋爐房事故原

2 accident reason analysis

Analysis of gas boiler room the cause of the accident, there are two possible: boiler ontology explosion, boiler room to explode gas explosion concentration and explosions.

Boiler blast furnace body, because be in, or flue gas mixture in explosive existence, when achieved by fire or explosion limit, boiler heat ignites causing accidents in itself. This point and the national norm of building fire system that conform to the relevant provisions. The actual current boiler proct has considered safe proction measures to avoid it. Qualified gas boiler itself has the explosion-proof process design, such as burner in abnormal situation automatic stop, self-control device also stop output fuel, Gas boiler combustion system higher automatization, including the gas pressure is high, low limit alarm protection, when the control logic where step does not meet the conditions set start corresponding interlock protection.

Avoid the boiler exploded possibility, but still ontology exist above another possibility, can avoid? How to avoid it?

Three measures

In fact in design, according to the boiler design code "and" automatic fire alarm system design code "GB50116-1998 etc standard, we have taken the following measures:

Natural gas pipelines valves, meter, may occur gas leak place, boiler room may proce gas storage proct area [relative density 0.8, it is to be in commonly roof area in these areas], all equipped with combustible gas concentration measurement alarm device, according to combustible gas concentration situation give out sound and light alarm signal and start exhaust fan, when leakage accident concentrations reach explosion limit of the lower limit 50% [this value for reference only], but also immediately close natural air intake ct total intake solenoid valves.

In the boiler room and a natural gas pipeline in and out of the room, the incident, but also with the smoke exhaust fan combustible gas alarm interlocking (start).

Electrical, instrument by cable selection TongXin, not less than 1.5 mm2 minimum section.

Gas radiation tube tube top or the nearby, the lightning rod should be installed above the pipe jacking tip should be not less than 3m, and its scope of protection tube top above not less than 1-m.

Gas pipeline should be static grounding device that, when pipeline as metal materials, and lightning protection or electrical engineering protective grounding wire connected, the measured resistance R more than 4 Ω. In pipe joints, such as the bend, flange, valve and pipe with good place cannot metal contact, also with metal soft line will be both ends jumper.

In the boiler room and a natural gas pipeline in and out of the room door, window take pressure measures.

According to the explosion and fire dangerous environment electrical device design specification "the laws 2.2.2 bar, accord with one of the following conditions may, when the explosion danger area: devin in item 3, in the process of proction use fire equipment near, A combination of these several measures can clearly, electrical equipment selection for the explosion.

At the same time according to the explosion and fire dangerous environment electrical device design specification "the laws 2.2.2 bar, accord with one of the following conditions may, when the explosion danger area devin: the first 2 items, and the highest possible flammable explosive chroma does not exceed 10% of the lower limit, Close air intake ct natural total intake solenoid valves, concentration exceed 10% of the lower limit explosion limit, boiler room near the roof area are gas storage proct area, so lighting lamps and lanterns and switch choosing is explosion-proof type.

4 conclusion

In gas boiler room electrical design, lighting choose explosion-proof lamps, other part adopts the explosion-proof type.

references

[1] boiler design standard. GB50041-1992.

[2] explosion and fire dangerous environment electrical device design standard. GB50058-1992.

[3] the code for fire protection design of buildings. GB50016-2006.

[4] automatic fire alarm system design standard. GB50116-1998.

C. 焦爐煤氣鍋爐房牆壁上的軸流風機(防爆型)安裝高度有要求嗎,鍋爐房凈高8.5米,我安裝在3.5米的高度合適

按中間偏下就好,參考防爆氣體和空氣比重理解,記得粉我

D. 燃氣鍋爐房電氣必須防爆嗎

室外燃氣鍋爐電氣設備不用考慮防爆。只有在燃氣分配站區域的電氣設備要考慮防爆。

E. 燃氣鍋爐房 是不是防暴區

GB50016 第3/3/12說明在有明火的設備附近不劃分為防爆區。城鎮燃氣規范也規定鍋版爐房為丁類權,不劃分防爆區。GB50058第2。2.2也有此規定。因為在這些區域光一個電氣防爆沒有意義,你都有明火了還用得著電氣那點小火花來點燃?所以,一般不劃分為防爆區,但裝備氣體報警,防爆事故通風設施(事故通風要防爆是因為事故是濃度是已達到爆炸極限)。

F. 燃氣鍋爐房鍋爐間電氣設備要求防爆嗎

一般情況下,燃氣鍋爐房的電氣設備是沒有防爆要求的。按要求做好管道的防靜電接地就足夠了。

G. 天燃氣鍋爐房防爆裝置都有什麼

防爆燈,防爆聲光報警器,防爆電氣控制設備,輸送氣體管道上的防爆儀表,

H. 鍋爐房泄爆面積

朋友,這個復規定在:GB50041-2008《鍋爐房設制計規范》
15.1.2鍋爐房的外牆、樓地面或屋面,應有相應的防爆措施。並應有相當於鍋爐間佔地面積10%的泄壓面積,泄壓方向不得朝向人員聚集的場所、房間和人行通道,泄壓處也不得與這些地方相鄰。地下鍋爐房採用豎井泄爆方式時,豎井的凈橫斷面積,應滿足泄壓面積的要求。
當泄壓面積不能滿足上述要求時,可採用在鍋爐房的內牆和頂部(頂棚)敷設金屬爆炸減壓板作補充。
註:泄壓面積可將玻璃窗、天窗、質量小於等於120kg/m2的輕質屋頂和薄弱牆等面積包括在內。

I. 燃氣鍋爐房應該設置防爆型感煙探測器嗎

這個要聽廠家意見,有的燃氣鍋爐就有探測器,一旦升溫失敗或者其他故障會自動警報的,
鍋爐房可以裝個防爆型感煙探測器,裝上更好不裝的話也不礙事。

閱讀全文

與燃氣鍋爐房電氣設備防爆相關的資料

熱點內容
超聲波牙刷怎麼使用視頻 瀏覽:644
承攬小型機械工程活怎麼樣 瀏覽:856
閥門中體大體有什麼區別 瀏覽:658
美食攝影器材怎麼挑選 瀏覽:509
燕秀工具箱30 瀏覽:619
機械加工積銷瘤是什麼意思 瀏覽:971
化工甲類乙類裝置設計規范 瀏覽:203
線上教育設備哪個好 瀏覽:321
空氣體積分數的實驗裝置圖 瀏覽:934
狼派機械鍵盤按鍵怎麼取 瀏覽:546
海馬600氦氣閥門 瀏覽:328
公務員考農業機械管理站如何 瀏覽:713
哈弗h9後備箱工具箱 瀏覽:106
儀表盤帶D的什麼車 瀏覽:624
主設備傳送模式什麼意思 瀏覽:521
13款朗逸車儀表怎麼調 瀏覽:892
如何用電工技術實驗裝置 瀏覽:626
宇明不銹鋼閥門廠電話 瀏覽:41
電廠滑動軸承怎麼做 瀏覽:831
重力工具箱部分 瀏覽:554