① 求一位大俠幫忙把論文翻譯成英文~100分 謝謝 燃氣鍋爐房的電氣防爆設計 摘 要:通過分析燃氣鍋爐房事故原
2 accident reason analysis
Analysis of gas boiler room the cause of the accident, there are two possible: boiler ontology explosion, boiler room to explode gas explosion concentration and explosions.
Boiler blast furnace body, because be in, or flue gas mixture in explosive existence, when achieved by fire or explosion limit, boiler heat ignites causing accidents in itself. This point and the national norm of building fire system that conform to the relevant provisions. The actual current boiler proct has considered safe proction measures to avoid it. Qualified gas boiler itself has the explosion-proof process design, such as burner in abnormal situation automatic stop, self-control device also stop output fuel, Gas boiler combustion system higher automatization, including the gas pressure is high, low limit alarm protection, when the control logic where step does not meet the conditions set start corresponding interlock protection.
Avoid the boiler exploded possibility, but still ontology exist above another possibility, can avoid? How to avoid it?
Three measures
In fact in design, according to the boiler design code "and" automatic fire alarm system design code "GB50116-1998 etc standard, we have taken the following measures:
Natural gas pipelines valves, meter, may occur gas leak place, boiler room may proce gas storage proct area [relative density 0.8, it is to be in commonly roof area in these areas], all equipped with combustible gas concentration measurement alarm device, according to combustible gas concentration situation give out sound and light alarm signal and start exhaust fan, when leakage accident concentrations reach explosion limit of the lower limit 50% [this value for reference only], but also immediately close natural air intake ct total intake solenoid valves.
In the boiler room and a natural gas pipeline in and out of the room, the incident, but also with the smoke exhaust fan combustible gas alarm interlocking (start).
Electrical, instrument by cable selection TongXin, not less than 1.5 mm2 minimum section.
Gas radiation tube tube top or the nearby, the lightning rod should be installed above the pipe jacking tip should be not less than 3m, and its scope of protection tube top above not less than 1-m.
Gas pipeline should be static grounding device that, when pipeline as metal materials, and lightning protection or electrical engineering protective grounding wire connected, the measured resistance R more than 4 Ω. In pipe joints, such as the bend, flange, valve and pipe with good place cannot metal contact, also with metal soft line will be both ends jumper.
In the boiler room and a natural gas pipeline in and out of the room door, window take pressure measures.
According to the explosion and fire dangerous environment electrical device design specification "the laws 2.2.2 bar, accord with one of the following conditions may, when the explosion danger area: devin in item 3, in the process of proction use fire equipment near, A combination of these several measures can clearly, electrical equipment selection for the explosion.
At the same time according to the explosion and fire dangerous environment electrical device design specification "the laws 2.2.2 bar, accord with one of the following conditions may, when the explosion danger area devin: the first 2 items, and the highest possible flammable explosive chroma does not exceed 10% of the lower limit, Close air intake ct natural total intake solenoid valves, concentration exceed 10% of the lower limit explosion limit, boiler room near the roof area are gas storage proct area, so lighting lamps and lanterns and switch choosing is explosion-proof type.
4 conclusion
In gas boiler room electrical design, lighting choose explosion-proof lamps, other part adopts the explosion-proof type.
references
[1] boiler design standard. GB50041-1992.
[2] explosion and fire dangerous environment electrical device design standard. GB50058-1992.
[3] the code for fire protection design of buildings. GB50016-2006.
[4] automatic fire alarm system design standard. GB50116-1998.
② 防爆電氣的作用
防爆電氣設備作為一個高科技的產物,其在最近的今年市場上的佔有率可謂是一路攀升,同樣的一個設備,其在安全性上面有了保障,那麼無論是對於設備的操作者還是其他的一方面的行為,更是有著更為重要的影響,同樣的一個市場狀況,安全性可謂是更為重要的一個方面,以此來說的話。我們在這樣一個背景之下,更為安全的哪一個就是我們要首選的一個。
其次在防爆的等級上面所出現的不同,防爆電氣設備,他們對於防爆的等級是有著不同的一個分別,同樣的一個東西,在等級上出現了一個產別,這就需要去挑選那些符合自己的習慣或者是自己的,這樣的話才能夠做到不被紛亂的世界所影響,再者說了挑選好了一個等級的東西,其對於以後的標准更是有了一個突出性的展示,以此方面來講的話,這樣的行為還涉及很嫩能夠讓人理解的,
最後是說防爆電氣設備在很多的時候還是需要大家對於其正確的進行操作,畢竟隨然說是一個、中防爆的設備,但實際也不是說能夠任意的進行操作,任意的行為只能是引發更多不同的狀態,這也是自己在這方面的一個警告,並不是說只要購買了這樣的產品就一定能夠保證生產的安全,還是在自己的是使用等過程呢個之中、要嚴格的把握質量關,這樣才能夠更好的完成生產任務,於此同時更好的去學習和實踐這樣的設備,才能更好的對其使用。
③ 電氣設備防爆目的和意義
電氣設備防爆目的是防止高危環境引起短路,火災,觸電等事故。
④ 防爆電氣設備的設計原理和要求是什麼
普通電氣抄設備引起氣體爆炸火災的原因主要有:
電氣設備產生的火花和電弧;電氣設備表面(指與可燃性氣體混合物相接觸的表面)發熱。基本防爆設計原理:一是將在正常運行時能產生電弧和火花的設備或部件,放入隔爆外殼內,或採取澆封型、充砂型、充油型等防爆型式實現防爆目的。二是針對正常運行不會產生電弧、火花和危險高溫的增安型電氣設備,在其結構上採取一些保護措施,提高其安全性和可靠性,使其在正常運行或認可的過載條件下不會產生電弧、火花過熱和引燃源,避免引起爆炸和火災。對於粉塵防爆電氣設備:一般是按規定條件設計製造,其外殼能阻止或減少可燃粉塵的進入,並不會妨礙設備安全運行和點燃的粉塵,引起爆炸。
以上內容均根據學員實際工作中遇到的問題整理而成,供參考,如有問題請及時溝通、指正。
⑤ 跪求:某化工廠降壓變電所的電氣設計 的畢業論文 有開題報告最好 急!急!急!
網上找個文庫,那裡有好多~!
⑥ 電氣設備的防爆措施有那些
選用專用的防爆電氣設備 有隔爆的 本安的 正壓的 通常設備用隔爆的回 儀表用本安活或增安的 具體等級答根據現場可燃物類型和點燃溫度決定 參見GB50058 《爆炸和火災危險環境電力裝置設計規范》
⑦ 防爆電氣的原理是什麼
爆炸的發生需要一定的前提即氧氣、爆炸性物質、引爆源,只有當這三者在一定區域同時存在時才有可能發生爆炸,這就是所謂的爆炸三角形原理。而我們要做的就是控制這三個條件中的一個或多個。在生產過程中大量使用電氣儀表,各種磨擦的電火花 , 機械磨損火花、靜電火花、高溫等不可避免,尤其當儀表、電氣發生故障時,會滿足爆炸條件。
當爆炸性物質與氧氣的混合濃度處於爆炸極限范圍內時將會發生爆炸。因此採取防爆就顯得很必要了。於是人們採取了多種防爆電氣技術方法,防止爆炸危險性環境形成及其爆炸,所以我們就是要控制在爆炸性環境中工作的物體既引爆源這就是防爆。
⑧ 電氣防火與防爆
電氣防火防爆基本措施有哪些
根據場所特點電氣防火防爆所採取的基本措專施有:
(1)正確選用電屬氣設備。具有爆炸危險場所應按規范選擇防爆電氣設備。
(2)按規范選擇合理的安裝位置,保持必要的安全間距是防火防爆的一項重要措施。
(3)加強維護保養檢修,保持電氣設備正常運行:包括保持電氣設備的電壓、電流、溫升等參數不超過允許值,保持電氣設備足夠的絕緣能力,保持電氣連接良好等。
(4)通風:在爆炸危險場所,如有良好的通風裝置,能降低爆炸性混合物的濃度。
(5)採用耐火設施對現場防火有很重要的作用。如為了提高耐火性能,木質開關箱內表面襯以白鐵皮。
(6)接地:爆炸危險場所的接地(或接零),較一般場所要求高。必須按規定接地。
⑨ 電氣防火防爆技術是什麼
(一)消除或減少爆炸性混合物(二)隔離和間距 危險性大的設備應分室安裝,並在版隔牆上採取封堵措施權;高壓、充油的電氣裝置,應與爆炸危險區域保持規定的安全距離。(三)消除引燃源 1、按爆炸危險環境的特徵和危險物的級別、組別選用電氣設備和設計電氣線路。 2、保持電氣設備和電氣線路安全運行。(四)保護接地 1、應將所有不帶電金屬物件做等電位聯結。 2、如低壓由接地系統配電,採用TN-S系統。 3、如低壓由不接地系統配電,採用IT系統。